| Item | Fireclay Series | |||||||||
| Code | N-1 | N-2a | N-2b | N-3a | N-3b | N-4 | N-5 | N-6 | ||
| Al2O3 | ≥ | % | ||||||||
| Refractoriness | ≥ | ºC | 1750 | 1730 | 1730 | 1710 | 1710 | 1690 | 1670 | 1580 |
| RUL 0.2Mpa | ≥ | 1400 | 1350 | 1320 | 1300 | |||||
| PLC % | 1500ºC×2h | |||||||||
| 1400ºC×2h | 0.1 | 0.1 | 0.2 | |||||||
| -0.4 | -0.5 | -0.5 | ||||||||
| 1350ºC×2h | 0.2-0.5 | 0.2-0.5 | 0.2-0.5 | 0.2-0.5 | ||||||
| AP | ≤ | % | 22 | 24 | 26 | 24 | 26 | 24 | 26 | 28 |
| CCS | ≥ | Mpa | 30 | 25 | 20 | 20 | 15 | 20 | 15 | 15 |
| Item | Performance Indicators | |||
| DN-12 | DN-15 | |||
| Al2O3 | ≥ | % | 45 | 42 |
| Fe2O3 | ≤ | 1.2 | 1.5 | |
| AP | ≤ | 12 | 15 | |
| BD | ≥ | g/cm3 | 2.37 | 2.30 |
| CCS | ≥ | MPa | 68 | 58.8 |
| RUL T0.6 T0.5 | ≥ | ºC | 1500 | 1470 |
| 1470 | 1450 | |||
| Thermal shock stability (1100ºC-water cooling) | Provide the measured data | |||
| PLC (1400ºC×2h) | % | -0.1 | -0.2 | |
| 0.05 | 0 | |||
| Note: Differential method is used for load-soft temperature arbitration. |
| Item | Performance Indicators | |||
| BN-40a | BN-40b | |||
| Al2O3 | ≥ | % | 40 | 40 |
| Fe2O3 | ≤ | 1.5 | 1.8 | |
| A.P | ≤ | 18 | 18 | |
| B.D | ≥ | g/cm3 | 2.30 | 2.30 |
| CCS | ≥ | MPa | 49 | 34.3 |
| RUL T0.2 | ≥ | ºC | 1450 | 1400 |
| PLC (1400ºC×2h) | % | 0 | ||
| -0.4 0 |