ABB ttf200 ttf300 temperature transmitter With TTF200 and T
Price: 23
ABB ttf200 ttf300 temperature transmitter
With TTF200 and TTF300 field-mount temperature transmitters, ABB offers cost-effective solutions for both standard applications and applications that are more demanding. A version with stainless steel housing allows it to be used in harsh ambient conditions at temperatures down to –50 °C (–58 °F). The devices are available with an indicator, which optionally also allows configuration on site without additional handheld terminal. Sensor redundancy, sensor drift monitoring and freestyle characteristic are available. The TTF300 comes with an optional wireless model, the TTF300-W.
Email: anna@cwlyautomation.com Tel: +86 13667121125 whatsapp/ vk/ telegram also available Company: Hongkong CW Green Tech Company
PRODUCT DETAILS
TTF200 field-mount temperature transmitters
Field Mountable One Sensor Input Resistance thermometers, resistance-type remote sensors (0 to 5000 Ohm) Thermocouples, voltages, mV-voltages (–125 to 1100 mV) Pt100, two-wire, three-wire, four-wire, thermocouple with internal reference junction Continuous sensor monitoring and self-monitoring Supply voltage monitoring Wire break and corrosion monitoring Sensor error adjustment Electrical isolation Transmitter-controlled graphical indicator LCD indicator for process value, sensor value and actual value HART Configurable
Email: anna at cwlyautomation dot com Tel: +86 13667121125 whatsapp/ vk/ telegram also available Company: Hongkong CW Green Tech Company
TTF300 field-mount temperature transmitters
Wireless option available Field mount, single-compartment housing, two cable glands Two sensor inputs Resistance thermometers, resistance-type remote sensors (0 to 5000 Ohm) Thermocouples, voltages, mV voltages (–125 to 1100 mV) Pt100, two-wire, three-wire, four-wire, thermocouple with internal reference junction 2x Pt100 two-wire and three-wire, 2x thermocouple or 1x Pt100 two-wire, three-wire, four-wire and 1x thermocouple Continuous sensor monitoring and self- monitoring Supply voltage Wire break and corrosion monitoring Sensor error adjustment Electrical isolation Specific linearization Callendar-Van Dusen coefficient, value pair table / 32 points Transmitter-controlled, graphical LCD indicator with dual function Configuration of the transmitter via buttons Process, sensor and actual values display HART Configurable Example Configuration
Email: anna at cwlyautomation dot com Tel: +86 13667121125 whatsapp/ vk/ telegram also available Company: Hongkong CW Green Tech Company
TTF300.L3.C.2.H.BS.K2.T0.M5 TTF300: Field mounted, Pt100 (RTD), thermocouples, electrical isolation ? L3: Explosion protection- FM Explosion Proof (XP): XP, DIP, Class I, II, III, Div. 1+2, Groups A-G, factory sealed ? C: Housing/display- single-compartment housing (aluminum) / with LCD display HMI ? 2: Cable entry- thread 2 x 1/2″ NPT (National Pipe Thread) ? H: Communication protocol- HART, programmable, output signal 4-20mA ? BS: Configuration- standard ? K2: Mounting bracket- wall mounting / 2” pipe mounting bracket (stainless steel) ? T0: Device identification plate- plate stainless steel ? M5: Documentation language- English
SEND INQUIRY
Please fill in fully your information to send email